Safety Concern for Class I, Division 1, Group AB and Zone 0 Group IIC Installations of VEGA PLICSCOM
- Type of Notification: Product Safety Notification
- FM Approval Status: FM Approved
FM Approvals has been made aware that the VEGA PLICSCOM display module may, in rare cases, result in an energy level exceeding the allowable limits for intrinsic safety gas groups AB / IIC.
Company Identity: VEGA Grieshaber KG
Product Identity:
VEGAFLEX 80 Series, Level Measurement Equipment
VEGABAR 80 Series, Pressure Sensor Transmitters
VEGAPULS 6X, Level Transmitters
VEGAPULS 64/69, Level Transmitters
Nameplate Data:
FM Approvals Certificate Numbers as follows:
VEGAFLEX 80 Series: FM16US0403X
VEGABAR 80 Series: FM16US0044X
VEGAPULS 6X: FM22US0038X & FM22CA0026X
VEGAPULS 64/69: FM20US0103X
Number of Units Impacted: 2700 units containing a PLICSCOM display module manufactured between March 2021 to May 2024.
FM Approval Status: FM Approved
Hazard Involved: Units containing the PLICSCOM display module are capable of producing an internal voltage which exceeds the allowable limits for intrinsic safety for gas groups AB / IIC; thereby becoming a potential ignition source. This is only a concern for units used in gas groups AB or IIC. VEGA is addressing the safety concern by supplying modified PLICSCOM display modules. Customers in North America who may be in possession of these units where they are used in gas groups AB / IIC have been notified and will be provided replacement PLICSCOM display modules.
Using This Product?
If you suspect you are in possession of these units bearing the FM Approvals certification marking, please contact your local VEGA contact person.
Antonio Pires
Norwood, MA, United States
+1 (1) 781-255-4825